Fulltext available Open Access
DC FieldValueLanguage
dc.contributor.authorDietrich, Udo-
dc.contributor.authorGarcia Rios, Laura-
dc.date.accessioned2022-10-25T08:40:14Z-
dc.date.available2022-10-25T08:40:14Z-
dc.date.issued2018-
dc.identifier.citationSustainable Development and Planning Xen_US
dc.identifier.isbn978-1-78466-291-2-
dc.identifier.isbn978-1-78466-292-9-
dc.identifier.urihttps://repos.hcu-hamburg.de/handle/hcu/799-
dc.description.abstractSalvador, Brazil was chosen as the location for a hot and humid climate. Temperatures lay in the range between 25 and 32°C in the hot period (around December) and 22 and 27°C in the cooler one (around June). An assessment of the outdoor temperatures with adaptive comfort model EN 15251 shows that with only natural ventilation there are good chances to reach comfort. Overheating may arise from internal use, artificial light and solar heat transfer through windows as well as through opaque walls and roofs (exterior surfaces absorb solar radiation, construction heats up and the high-temperature transfers remarkably through the construction to the interior). Representative local traditional and contemporary buildings were selected and analysed with transient thermal simulation. Results show that the heat transfer through the constructions is in case of overheating the dominant component. In both buildings, the last floor under the roof overheats. Only with an improvement of the construction (by adding layers that contribute to thermal insulation) comfort can be reached. The intermediate floor in the traditional building with thick adobe walls (60 cm) behaves very well, while the contemporary building with thin concrete walls (10 cm) overheats. Comfort can be reached only by bringing the wall into shadow (cladding) or optimizing the construction by adding insulation or replacing concrete with hollow bricks, increased natural (shaft) ventilation and shading of the windows. Positively it has to be said that, in the local contemporary architecture itself with building shape, (moderate) size and placement of windows, shading system, cross ventilation is not a fundamental obstacle to reach comfort. In other countries, the trend to bigger windows leads without AC in any case already to discomfort. But the tendency to construct cost-optimized, to use “modern” materials like concrete (without protecting cladding or insulation) and the hope that users will install AC has led to non-optimal constructions. Detailed recommendations for the improvement of roof and wall constructions are given in the paper.en
dc.language.isoenen_US
dc.publisherWIT Press-
dc.subjecthot and humid climateen
dc.subjectadaptive comfort modelen
dc.subjectnatural ventilationen
dc.subjectheat transfer through constructionsen
dc.subjecttransient thermal simulationen
dc.subjecttraditional architectureen
dc.subjectcontemporary architectureen
dc.subject.ddc624: Ingenieurbau und Umwelttechnik-
dc.titlePassive Adaptive Strategies for the Optimisation of Comfort and Energy Demand in Traditional and Contemporary Buildings in Hot, Humid Climatesen
dc.typeinBook-
dc.type.dinibookPart-
dc.type.driverbookPart-
dc.type.casraiBook Chapter-
dcterms.DCMITypeText-
tuhh.identifier.urnurn:nbn:de:gbv:1373-repos-10187-
tuhh.oai.showtrueen_US
tuhh.publisher.doi10.2495/SDP180041-
tuhh.publication.instituteBauphysiken_US
tuhh.type.opusInBuch (Kapitel / Teil einer Monographie)-
tuhh.container.startpage39en_US
tuhh.container.endpage49en_US
tuhh.relation.ispartofseriesnumber217en_US
tuhh.relation.ispartofseriesWIT Transactions on Ecology and the Environmenten_US
tuhh.type.rdmfalse-
openaire.rightsinfo:eu-repo/semantics/openAccessen_US
item.grantfulltextopen-
item.creatorOrcidDietrich, Udo-
item.creatorOrcidGarcia Rios, Laura-
item.fulltextWith Fulltext-
item.seriesrefWIT Transactions on Ecology and the Environment;217-
item.languageiso639-1en-
item.tuhhseriesidWIT Transactions on Ecology and the Environment-
item.openairecristypehttp://purl.org/coar/resource_type/c_3248-
item.cerifentitytypePublications-
item.creatorGNDDietrich, Udo-
item.creatorGNDGarcia Rios, Laura-
item.openairetypeinBook-
crisitem.author.deptBauphysik-
crisitem.author.orcid0000-0002-1955-026X-
Appears in CollectionPublikationen (mit Volltext)
Files in This Item:
File Description SizeFormat
SDP18004FU1.pdf652.74 kBAdobe PDFView/Open
Show simple item record

Page view(s)

363
checked on Dec 24, 2024

Download(s)

71
checked on Dec 24, 2024

Google ScholarTM

Check

Export

Items in repOS are protected by copyright, with all rights reserved, unless otherwise indicated.