Please use this identifier to cite or link to this item: https://doi.org/10.34712/142.81-1
Fulltext available Open Access
DC FieldValueLanguage
dc.contributor.authorDollhopf, Stefan-
dc.date.accessioned2026-05-27T07:50:57Z-
dc.date.available2026-05-27T07:50:57Z-
dc.date.issued2026-04-24-
dc.identifier.citationTechnical Infrastructure Management : Insights Vol. IIen_US
dc.identifier.isbn978-3-947972-92-0en_US
dc.identifier.urihttps://repos.hcu-hamburg.de/handle/hcu/1245-
dc.description.abstractThe transformation of district heating networks (DHN) towards lower operating temperatures and more dynamic operating conditions provides an occasion to examine the mechanical and thermal behaviour of buried pre-insulated bonded pipes under these new conditions in detail. This paper presents the development and implementation of a full-scale pipe test bench (PTB) at the District Lab research facility in Kassel, Germany, established within the UrbanTurn research project. The PTB consists of a buried pipe loop with high- and low-temperature circuits and two test fields with different bedding materials, enabling an experimental investigation of pipe–soil interaction. A comprehensive measurement concept was implemented, comprising 54 local sensors and a distributed fibre-optic temperature monitoring system along the test section. The paper documents the iterative design process, the alignment of investigation objectives with the technical infrastructure, and the practical implementation under real construction conditions. The results highlight key challenges in integrating measurement technology into civil engineering works and underline the importance of detailed as-built documentation for experimental infrastructure.en
dc.language.isoenen_US
dc.publisherHafenCity Universität Hamburgen_US
dc.subjectdistrict heating pipesen
dc.subjecttest fielden
dc.subjectmeasurementen
dc.subjectrecycling materialen
dc.subjectdistrict laben
dc.subject.ddc624: Ingenieurbau und Umwelttechniken_US
dc.titleFrom Concept to Implementation: Hands on the pipe test bench at District Lab in Kasselen
dc.typeinBooken_US
dc.identifier.doi10.34712/142.81-1en_US
dc.type.diniBookPart-
dc.subject.gndFernwärmeleitungen_US
dc.subject.gndVersuchsstreckeen_US
dc.subject.gndMesstechniken_US
dc.subject.gndRecyclingen_US
dc.type.driverbookPart-
dc.type.casraiBook Chapter-
dcterms.DCMITypeText-
tuhh.identifier.urnurn:nbn:de:gbv:1373-repos-16367-
tuhh.oai.showtrueen_US
tuhh.publisher.doi10.34712/142.81-
tuhh.publication.instituteTechnisches Infrastrukturmanagementen_US
tuhh.type.opusInBuch (Kapitel / Teil einer Monographie)-
tuhh.container.startpage15en_US
tuhh.container.endpage24en_US
tuhh.relation.ispartofseriesnumber2en_US
tuhh.relation.ispartofseriesTechnical Infrastructure Management - Insightsen_US
tuhh.type.rdmfalse-
openaire.rightsinfo:eu-repo/semantics/openAccessen_US
local.contributorPerson.editorWeidlich, Ingo-
item.grantfulltextopen-
item.creatorOrcidDollhopf, Stefan-
item.seriesrefTechnical Infrastructure Management - Insights;2-
item.fulltextWith Fulltext-
item.creatorGNDDollhopf, Stefan-
item.tuhhseriesidTechnical Infrastructure Management - Insights-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_3248-
item.openairetypeinBook-
item.cerifentitytypePublications-
crisitem.author.deptTechnisches Infrastrukturmanagement-
crisitem.author.orcid0009-0008-7522-8743-
Appears in CollectionPublikationen (mit Volltext)
Files in This Item:
File Description SizeFormat
2026-04-24_TIM-Insights-Vol-2_142.81-1_Dollhopf.pdf3.53 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Export

Items in repOS are protected by copyright, with all rights reserved, unless otherwise indicated.