Fulltext available Open Access
Type: Chapter (Book)
Title: Passive Adaptive Strategies for the Optimisation of Comfort and Energy Demand in Traditional and Contemporary Buildings in Hot, Humid Climates
Authors: Dietrich, Udo 
Garcia Rios, Laura
Source: Sustainable Development and Planning X
Issue Date: 2018
Keywords: hot and humid climate; adaptive comfort model; natural ventilation; heat transfer through constructions; transient thermal simulation; traditional architecture; contemporary architecture
Abstract: 
Salvador, Brazil was chosen as the location for a hot and humid climate. Temperatures lay in the range between 25 and 32°C in the hot period (around December) and 22 and 27°C in the cooler one (around June). An assessment of the outdoor temperatures with adaptive comfort model EN 15251 shows that with only natural ventilation there are good chances to reach comfort. Overheating may arise from internal use, artificial light and solar heat transfer through windows as well as through opaque walls and roofs (exterior surfaces absorb solar radiation, construction heats up and the high-temperature transfers remarkably through the construction to the interior). Representative local traditional and contemporary buildings were selected and analysed with transient thermal simulation. Results show that the heat transfer through the constructions is in case of overheating the dominant component. In both buildings, the last floor under the roof overheats. Only with an improvement of the construction (by adding layers that contribute to thermal insulation) comfort can be reached. The intermediate floor in the traditional building with thick adobe walls (60 cm) behaves very well, while the contemporary building with thin concrete walls (10 cm) overheats. Comfort can be reached only by bringing the wall into shadow (cladding) or optimizing the construction by adding insulation or replacing concrete with hollow bricks, increased natural (shaft) ventilation and shading of the windows. Positively it has to be said that, in the local contemporary architecture itself with building shape, (moderate) size and placement of windows, shading system, cross ventilation is not a fundamental obstacle to reach comfort. In other countries, the trend to bigger windows leads without AC in any case already to discomfort. But the tendency to construct cost-optimized, to use “modern” materials like concrete (without protecting cladding or insulation) and the hope that users will install AC has led to non-optimal constructions. Detailed recommendations for the improvement of roof and wall constructions are given in the paper.
Subject Class (DDC): 624: Ingenieurbau und Umwelttechnik
HCU-Faculty: Bauphysik 
Start page: 39
End page: 49
Publisher: WIT Press
Part of Series: WIT Transactions on Ecology and the Environment 
Volume number: 217
ISBN: 978-1-78466-291-2
978-1-78466-292-9
Publisher DOI: 10.2495/SDP180041
URN (Citation Link): urn:nbn:de:gbv:1373-repos-10187
Directlink: https://repos.hcu-hamburg.de/handle/hcu/799
Language: English
Appears in CollectionPublikationen (mit Volltext)

Files in This Item:
File Description SizeFormat
SDP18004FU1.pdf652.74 kBAdobe PDFView/Open
Staff view

Page view(s)

363
checked on Dec 23, 2024

Download(s)

71
checked on Dec 23, 2024

Google ScholarTM

Check

Export

Items in repOS are protected by copyright, with all rights reserved, unless otherwise indicated.